AirIndex Research · FAA LID 1FL9

HENDRY COUNTY FIRE-EMS

LA BELLE, FL. Operational · Private use.

OperationalPrivate usePrivate

Watch this facility

Get an email when the record for Hendry County Fire-EMS changes: its FAA registration, pad data, nearby FAA airspace determinations, or AirIndex findings. A weekly digest arrives only when something changed.

Already a reader? Sign in to watch it
Loading satellite view…

Data integrity

53/100
Self-reportedData Integrity Index
Independent inspection
Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 18 ft MSL · USGS ground 18 ft · Δ 0 ft
Structure cross-check (Overture / OSM)
On a building footprint — height not tagged in the source
Building height ≈ 12 ft — measured independently of the FAA record
Cross-source consensus
⚠ Sources conflict — pad is on a building, but FAA elevation reads ground level
Stale-low FAA elevation (the 6FD8 class) — never updated for the rooftop pad. Treat the recorded elevation as unreliable.

Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →

eVTOL readiness

INFEASIBLE WITHOUT REMEDIATIONConversion feasibility · four readings, one line each
Obstruction screen
Severe
High obstacle within 0.5 nm conflicts with the expanded footprint and the 8:1 approach surface.
Geometry
Meets the FATO footprint
Recorded pad side 100 ft against a 100 ft eVTOL FATO.
Structural FATO
Unverified
The full 100 × 100 ft FATO must be load-bearing. The FAA does not record structural capacity, so no record can confirm it.
Overall
Infeasible without remediation
A high obstacle conflicts with the expanded footprint. Remediation or a different site.
100 ft · eVTOL FATO100 ft
This pad already covers the eVTOL landing footprint as it stands.
recorded pad eVTOL FATO
Recorded pad (limiting side)
100 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.

Measured against FAA pad geometry and federal FATO sizing (EB-105). The obstruction screen is the only reading the engine verdict rests on; geometry and structural capacity are stated separately and never folded into it. A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.

FAA compliance

Q1 · FAA registrationPASS
Active FAA NASR 5010 record.
Q2 · Airspace determinationON_FILE
OE/AAA ASN 2024-ASO-5877-NRA: DET-to-Prop
Q3 · State enforcementSTRONG
State has adopted FAA AC as enforceable.
Q4 · NFPA 418ADOPTED
Jurisdiction has adopted NFPA 418 in fire/building code.

FAA facility data

FAA LID
1FL9
AIX ID
aix:hp:0VA7B1M8
Lat / Lng
26.74639, -81.42861
Elevation
18 ft MSL
Pad dimensions
100 × 100 ft
Surface type
CONC
Activation date
2000/04
Last owner update
2020/05/05

FAA OEAAA airspace determinations3

Airspace clearance
On file as archived / procedural records — no standing clearance to track.
Filing activity
Most recent determination 2025-03-19 · 1 in the last 24 months
  • NRADET-to-PropASN 2025-ASO-4102-NRA
    2025-04-09
    CONSTR. SAFETY PLAN - Miscellaneous · 15 ft AGL — CONSTR. SAFETY PLAN Miscellaneous
  • NRADET-to-PropASN 2024-ASO-5877-NRA
    2024-05-29
    CONSTR. SAFETY PLAN - Miscellaneous · 1 ft AGL — CONSTR. SAFETY PLAN Miscellaneous
  • NRADET-to-PropASN 2024-ASO-5835-NRA
    2024-04-18
    CONSTR. SAFETY PLAN - Miscellaneous · 67 ft AGL — CONSTR. SAFETY PLAN Miscellaneous
Blueprint
The record vs. what we measured
53/100
DATA INTEGRITY
Surface elevation
GROUND 18ftROOFTOP 30ftbldg ~12ftFAA FILED 18ft

The FAA record places this pad at 18 ft. USGS terrain plus the building put the actual rooftop at 30 ft — a +12 ft difference the federal record doesn’t carry.

eVTOL footprint
FATO 100 ft reqHTLOF 100 ft

Footprint assessment available.

SIGNALFEDERAL RECORDMEASURED
Surface elevation18 ft30 ft · USGS+structure
Structurenot on recordOn a building
Pad dimensions100 ft side (filed)100 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
Federal record
Cross-checkedUSGS · Overture · dimensions
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.
Request Ground Truth verification

Full risk assessment

This page is the public data-integrity record. The full RiskIndex assessment — Q1–Q5 compliance, dimensional / FATO analysis, an underwriting-grade risk score, peer benchmark, and a sealed Site Intelligence Report — is available on request.

Request the full assessment

Building autonomous systems? See the machine-verified feed

Provenance FAA NASR 5010 · pad dims APT cycle 2026/03/19 · USGS 3DEP terrain · Overture structure · eVTOL screen conversion-feasibility-1.1 · AIX-ID aix:hp:0VA7B1M8 · Methodology →
Cite this facility

HENDRY COUNTY FIRE-EMS, LA BELLE, FL (FAA 1FL9). AirIndex facility record aix:hp:0VA7B1M8. Verifiable at https://www.airindex.io/verify/aix:hp:0VA7B1M8.

Verify this record →

AIX-IDs are free to cite and reference; the registry is the source of record. The verify link resolves this record against the audit chain.

← All markets