AirIndex Research · FAA LID 22WI

HSHS ST CLARE MEML HOSPITAL

OCONTO FALLS, WI. Operational · Private use.

OperationalPrivate usePrivate

Watch this facility

Get an email when the record for Hshs St Clare Meml Hospital changes: its FAA registration, pad data, nearby FAA airspace determinations, or AirIndex findings. A weekly digest arrives only when something changed.

Already a reader? Sign in to watch it
Loading satellite view…

Data integrity

57/100
Self-reportedData Integrity Index
Independent inspection
Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 720 ft MSL · USGS ground 720 ft · Δ 0 ft
Structure cross-check (Overture / OSM)
Ground-level — no building footprint at the coordinate
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)

Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →

eVTOL readiness

UNVERIFIEDConversion feasibility · four readings, one line each
Obstruction screen
No data
No FAA obstacle data on file for this state. Clearance unverified.
Geometry
Requires 25 feet of expansion
Recorded pad side 75 ft against a 100 ft eVTOL FATO.
Structural FATO
Unverified
The full 100 × 100 ft FATO must be load-bearing. The FAA does not record structural capacity, so no record can confirm it.
Overall
Unverified
No obstruction data on file. The dimensional gap applies; clearance is unverified.
100 ft · eVTOL FATO75 ft
The recorded pad is 25 ft short of the 100 ft footprint an eVTOL would need — shown to scale.
recorded pad eVTOL FATO
Recorded pad (limiting side)
75 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.

Measured against FAA pad geometry and federal FATO sizing (EB-105). The obstruction screen is the only reading the engine verdict rests on; geometry and structural capacity are stated separately and never folded into it. A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.

FAA compliance

Q1 · FAA registrationPASS
Active FAA NASR 5010 record.
Q2 · Airspace determinationUNKNOWN
FAA OE/AAA airspace determination data integration pending.
Q3 · State enforcementUNKNOWN
State enforcement posture not yet assessed.
Q4 · NFPA 418UNKNOWN
NFPA 418 adoption status not yet assessed for this jurisdiction.

FAA facility data

FAA LID
22WI
AIX ID
aix:hp:2Z2QDJVC
Lat / Lng
44.86538, -88.12866
Elevation
720 ft MSL
Pad dimensions
75 × 75 ft
Surface type
TURF
Activation date
1991/09
Last owner update
2020/08/12

FAA OEAAA airspace determinations0

No FAA OEAAA determinations linked to this facility.
Blueprint
The record vs. what we measured
57/100
DATA INTEGRITY
eVTOL footprint
FATO 100 ft reqHTLOF 75 ft

The 75 ft pad is 25 ft short of the 100 ft an eVTOL FATO requires (measured).

SIGNALFEDERAL RECORDMEASURED
Surface elevation720 ftnot cross-checked
Structurenot on recordGround-level
Pad dimensions75 ft side (filed)75 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
Federal record
Cross-checkedUSGS · Overture · dimensions
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.
Request Ground Truth verification

Full risk assessment

This page is the public data-integrity record. The full RiskIndex assessment — Q1–Q5 compliance, dimensional / FATO analysis, an underwriting-grade risk score, peer benchmark, and a sealed Site Intelligence Report — is available on request.

Request the full assessment

Building autonomous systems? See the machine-verified feed

Provenance FAA NASR 5010 · pad dims APT cycle 2026/03/19 · USGS 3DEP terrain · Overture structure · eVTOL screen conversion-feasibility-1.1 · AIX-ID aix:hp:2Z2QDJVC · Methodology →
Cite this facility

HSHS ST CLARE MEML HOSPITAL, OCONTO FALLS, WI (FAA 22WI). AirIndex facility record aix:hp:2Z2QDJVC. Verifiable at https://www.airindex.io/verify/aix:hp:2Z2QDJVC.

Verify this record →

AIX-IDs are free to cite and reference; the registry is the source of record. The verify link resolves this record against the audit chain.

← All markets