AirIndex Research · FAA LID 5FL5

PALM BEACH COUNTY JUDICIAL CENTER

WEST PALM BEACH, FL. Operational · Private use.

OperationalPrivate usePrivate

Watch this facility

Get an email when the record for Palm Beach County Judicial Center changes: its FAA registration, pad data, nearby FAA airspace determinations, or AirIndex findings. A weekly digest arrives only when something changed.

Already a reader? Sign in to watch it
Loading satellite view…

Data integrity

54/100
Self-reportedData Integrity Index
Independent inspection
Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 297 ft MSL · USGS ground 19 ft · Δ 278 ft
Differential consistent with an elevated / rooftop pad
Structure cross-check (Overture / OSM)
On a building footprint — height not tagged in the source
Building height ≈ 278 ft — measured independently of the FAA record
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)

Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →

eVTOL readiness

INFEASIBLE WITHOUT REMEDIATIONConversion feasibility · four readings, one line each
Obstruction screen
Severe
High obstacle within 0.5 nm conflicts with the expanded footprint and the 8:1 approach surface.
Geometry
Requires 60 feet of expansion
Recorded pad side 40 ft against a 100 ft eVTOL FATO.
Structural FATO
Unverified
The full 100 × 100 ft FATO must be load-bearing. The FAA does not record structural capacity, so no record can confirm it.
Overall
Infeasible without remediation
A high obstacle conflicts with the expanded footprint. Remediation or a different site.
100 ft · eVTOL FATO40 ft
The recorded pad is 60 ft short of the 100 ft footprint an eVTOL would need — shown to scale.
recorded pad eVTOL FATO
Recorded pad (limiting side)
40 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.

Measured against FAA pad geometry and federal FATO sizing (EB-105). The obstruction screen is the only reading the engine verdict rests on; geometry and structural capacity are stated separately and never folded into it. A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.

FAA compliance

Q1 · FAA registrationPASS
Active FAA NASR 5010 record.
Q2 · Airspace determinationON_FILE
OE/AAA ASN 2026-ASO-1566-OE: CIR (study in circularization — under FAA review)
Q3 · State enforcementSTRONG
State has adopted FAA AC as enforceable.
Q4 · NFPA 418ADOPTED
Jurisdiction has adopted NFPA 418 in fire/building code.

FAA facility data

FAA LID
5FL5
AIX ID
aix:hp:9KN8H0FM
Lat / Lng
26.71541, -80.05440
Elevation
297 ft MSL
Pad dimensions
40 × 40 ft
Surface type
CONC
Activation date
1996/08
Last owner update
2019/12/09

Situations open at this facility1

highadverse determination nearbyopened 2026-09-13 · situation-rules-v1
Adverse FAA determination nearby: case 2026-ASO-14005-OE (CIR) 225 ft AGL, 0.70 nm from the facility, in the last 90 days.
Situations are rules-based inferences across the obstruction, observed-operations and record layers, re-evaluated nightly; each carries its evidence and closes when the condition no longer holds.

FAA OEAAA airspace determinations4

Airspace clearance
Airspace clearance on file has lapsed — a re-filing may be needed for new/continued operations. Does not by itself reclassify the existing structure as a hazard.
Clearance posture: expired 35d ago
Nearby obstructions (OE/AAA-determined structures)
4 structures determined near the pad · tallest 338 ft AGL
Active construction (crane / in-progress) filed recently — obstruction environment is changing.
Filing activity
Most recent determination 2026-01-22 · 4 in the last 24 months
  • OECIRASN 2026-ASO-1566-OE
    BUILDING · 338 ft AGL — S.W. Roof 1 Corner
  • OEDET-EBO-TMPexpires in 90dASN 2025-ASO-10480-OE
    2025-06-23
    CRANE$MOBILE · 219 ft AGL — NYULH TC1 Assist Crane
  • OEDET-DNE-TMPexpired 35d agoASN 2025-ASO-1844-OE
    2025-02-20
    CRANE$TOWER · 191 ft AGL — NYULH TC1
  • OEDET-DNEexpired 45d agoASN 2025-ASO-2279-OE
    2025-02-10
    BUILDING · 128 ft AGL — NYULH WPB Ambulatory Care
Blueprint
The record vs. what we measured
54/100
DATA INTEGRITY
eVTOL footprint
FATO 100 ft reqHTLOF 40 ft

The 40 ft pad is 60 ft short of the 100 ft an eVTOL FATO requires (measured).

SIGNALFEDERAL RECORDMEASURED
Surface elevation297 ft297 ft · USGS+structure
Structurenot on recordOn a building
Pad dimensions40 ft side (filed)40 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
Federal record
Cross-checkedUSGS · Overture · dimensions
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.
Request Ground Truth verification

Full risk assessment

This page is the public data-integrity record. The full RiskIndex assessment — Q1–Q5 compliance, dimensional / FATO analysis, an underwriting-grade risk score, peer benchmark, and a sealed Site Intelligence Report — is available on request.

Request the full assessment

Building autonomous systems? See the machine-verified feed

Provenance FAA NASR 5010 · pad dims APT cycle 2026/03/19 · USGS 3DEP terrain · faa_usgs_diff structure · eVTOL screen conversion-feasibility-1.1 · AIX-ID aix:hp:9KN8H0FM · Methodology →
Cite this facility

PALM BEACH COUNTY JUDICIAL CENTER, WEST PALM BEACH, FL (FAA 5FL5). AirIndex facility record aix:hp:9KN8H0FM. Verifiable at https://www.airindex.io/verify/aix:hp:9KN8H0FM.

Verify this record →

AIX-IDs are free to cite and reference; the registry is the source of record. The verify link resolves this record against the audit chain.

← All markets