AirIndex Research · FAA LID 5LA8

LA STATE POLICE TROOP D

LAKE CHARLES, LA. Operational · Private use.

OperationalPrivate usePublic

Watch this facility

Get an email when the record for La State Police Troop D changes: its FAA registration, pad data, nearby FAA airspace determinations, or AirIndex findings. A weekly digest arrives only when something changed.

Already a reader? Sign in to watch it
Loading satellite view…

Data integrity

79/100
CorroboratedData Integrity Index
Independent inspection
Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 15 ft MSL · USGS ground 10 ft · Δ 6 ft
Structure cross-check (Overture / OSM)
Ground-level — no building footprint at the coordinate
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)

Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →

eVTOL readiness

UNVERIFIEDConversion feasibility · four readings, one line each
Obstruction screen
No data
No FAA obstacle data on file for this state. Clearance unverified.
Geometry
Requires 88 feet of expansion
Recorded pad side 12 ft against a 100 ft eVTOL FATO.
Structural FATO
Unverified
The full 100 × 100 ft FATO must be load-bearing. The FAA does not record structural capacity, so no record can confirm it.
Overall
Unverified
No obstruction data on file. The dimensional gap applies; clearance is unverified.
100 ft · eVTOL FATO
The recorded pad is 88 ft short of the 100 ft footprint an eVTOL would need — shown to scale.
recorded pad eVTOL FATO
Recorded pad (limiting side)
12 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.

Measured against FAA pad geometry and federal FATO sizing (EB-105). The obstruction screen is the only reading the engine verdict rests on; geometry and structural capacity are stated separately and never folded into it. A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.

FAA compliance

Q1 · FAA registrationPASS
Active FAA NASR 5010 record.
Q2 · Airspace determinationON_FILE
OE3A archive: ASN 1999-ASW-2023-NRA determined 2002-09-05
Q3 · State enforcementUNKNOWN
State enforcement posture not yet assessed.
Q4 · NFPA 418UNKNOWN
NFPA 418 adoption status not yet assessed for this jurisdiction.

FAA facility data

FAA LID
5LA8
AIX ID
aix:hp:YG0K93JN
Lat / Lng
30.22713, -93.16257
Elevation
15 ft MSL
Pad dimensions
12 × 12 ft
Surface type
CONC
Surface condition
FAIR
Activation date
1985/02
Last owner update
2025/11/24

FAA OEAAA airspace determinations5

Airspace clearance
Airspace clearance on file is current.
Clearance posture: current (538d)
Nearby obstructions (OE/AAA-determined structures)
4 structures determined near the pad · tallest 215 ft AGL
Filing activity
Most recent determination 2026-07-02 · 4 in the last 24 months
  • OEDET-DNEcurrent (538d)ASN 2026-ASW-10727-OE
    2026-09-15
    TOWER · 215 ft AGL — Chennault Tower
  • OEDET-DNEcurrent (534d)ASN 2026-ASW-10740-OE
    2026-09-11
    BUILDING · 30 ft AGL — LC Fire Dept at Chennault
  • OEDET-DNEcurrent (534d)ASN 2026-ASW-10739-OE
    2026-09-11
    BUILDING · 30 ft AGL — LC Fire Dept at Chennault
  • OEDET-DNEcurrent (534d)ASN 2026-ASW-10742-OE
    2026-09-11
    BUILDING · 65 ft AGL — LC Fire Dept at Chennault
  • NRAARCH-DeterminedASN 1999-ASW-2023-NRA
    2002-09-05
    Other · 0 ft AGL — TROOP D PRIVATE-USE HELIPORT

Safety history (NTSB)1

Accident history

1 NTSB helicopter event within 3 nm since 2010 (1 accident); most recent 2010-06-26.

  • ACCIDENT1.7 nm
    2010-06-26
    AEROSPATIALE AS350 · Lake Charles, LANTSB CAROL

NTSB helicopter accidents & incidents geocoded within 3 nm of this pad and attributed to the nearest facility — proximity, not a determination that an event occurred at this site. Source: NTSB aviation accident database.

Blueprint
The record vs. what we measured
79/100
DATA INTEGRITY
eVTOL footprint
FATO 100 ft reqHTLOF 12 ft

The 12 ft pad is 88 ft short of the 100 ft an eVTOL FATO requires (measured).

SIGNALFEDERAL RECORDMEASURED
Surface elevation15 ftnot cross-checked
Structurenot on recordGround-level
Pad dimensions12 ft side (filed)12 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
Federal record
Cross-checkedUSGS · Overture · dimensions
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.
Request Ground Truth verification

Full risk assessment

This page is the public data-integrity record. The full RiskIndex assessment — Q1–Q5 compliance, dimensional / FATO analysis, an underwriting-grade risk score, peer benchmark, and a sealed Site Intelligence Report — is available on request.

Request the full assessment

Building autonomous systems? See the machine-verified feed

Provenance FAA NASR 5010 · pad dims APT cycle 2026/03/19 · USGS 3DEP terrain · Overture structure · eVTOL screen conversion-feasibility-1.1 · AIX-ID aix:hp:YG0K93JN · Methodology →
Cite this facility

LA STATE POLICE TROOP D, LAKE CHARLES, LA (FAA 5LA8). AirIndex facility record aix:hp:YG0K93JN. Verifiable at https://www.airindex.io/verify/aix:hp:YG0K93JN.

Verify this record →

AIX-IDs are free to cite and reference; the registry is the source of record. The verify link resolves this record against the audit chain.

← All markets