Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 1257 ft MSL · USGS ground 1214 ft · Δ 43 ft
Differential consistent with an elevated / rooftop pad
Structure cross-check (Overture / OSM)
Rooftop pad — the coordinate falls on a building footprint
Building height ≈ 24 ft — measured independently of the FAA record
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)
Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →
The recorded pad is 50 ft short of the 100 ft footprint an eVTOL would need — shown to scale.
recorded pad eVTOL FATO
Recorded pad (limiting side)
50 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.
Obstruction clearance
Clear — no obstructions within 0.5 nm on the FAA obstacle file
Measured against FAA pad geometry and federal FATO sizing (EB-105). A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.
MCDONNELL DOUGLAS HELICOPTER 369E · Mesa, AZ — NTSB CAROL
NTSB helicopter accidents & incidents geocoded within 3 nm of this pad and attributed to the nearest facility — proximity, not a determination that an event occurred at this site. Source: NTSB aviation accident database.
Blueprint
The record vs. what we measured
76/100
DATA INTEGRITY
Surface elevation
The FAA record places this pad at 1257 ft. USGS terrain plus the building put the actual rooftop at 1238 ft — a -19 ft difference the federal record doesn’t carry.
eVTOL footprint
The 50 ft pad is 50 ft short of the 100 ft an eVTOL FATO requires (measured).
SIGNALFEDERAL RECORDMEASURED
Surface elevation1257 ft1238 ft · USGS+structure
Structurenot on recordRooftop pad
Pad dimensions50 ft side (filed)50 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
✓Federal record
→
✓Cross-checkedUSGS · Overture · dimensions
→
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.
This page is the public data-integrity record. The full RiskIndex assessment — Q1–Q5 compliance, dimensional / FATO analysis, an underwriting-grade risk score, peer benchmark, and a sealed Site Intelligence Report — is available on request.