Get an email when the record for Med Trans Base changes: its FAA registration, pad data, nearby FAA airspace determinations, or AirIndex findings. A weekly digest arrives only when something changed.
Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 25 ft MSL · USGS ground 26 ft · Δ -1 ft
Structure cross-check (Overture / OSM)
Ground-level — no building footprint at the coordinate
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)
Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →
eVTOL readiness
INFEASIBLE WITHOUT REMEDIATIONConversion feasibility · four readings, one line each
Obstruction screen
Severe
High obstacle within 0.5 nm conflicts with the expanded footprint and the 8:1 approach surface.
Geometry
Requires 50 feet of expansion
Recorded pad side 50 ft against a 100 ft eVTOL FATO.
Structural FATO
Unverified
The full 100 × 100 ft FATO must be load-bearing. The FAA does not record structural capacity, so no record can confirm it.
Overall
Infeasible without remediation
A high obstacle conflicts with the expanded footprint. Remediation or a different site.
The recorded pad is 50 ft short of the 100 ft footprint an eVTOL would need — shown to scale.
recorded pad eVTOL FATO
Recorded pad (limiting side)
50 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.
Measured against FAA pad geometry and federal FATO sizing (EB-105). The obstruction screen is the only reading the engine verdict rests on; geometry and structural capacity are stated separately and never folded into it. A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.
Jurisdiction has adopted NFPA 418 in fire/building code.
FAA facility data
FAA LID
6FA3
AIX ID
aix:hp:4A2VZ79T
Lat / Lng
30.30037, -85.65909
Elevation
25 ft MSL
Pad dimensions
50 × 50 ft
Surface type
CONC
Activation date
2022/05
FAA OEAAA airspace determinations3
Airspace clearance
On file as archived / procedural records — no standing clearance to track.
Filing activity
Most recent determination 2021-11-24
NRAARCH-DeterminedASN 2021-ASO-6544-NRA2021-11-30
Heliport · 0 ft AGL — This NRA is an intentional duplicate and was only created in order to activate landing facility from 2017 with the latest OEAAA LAP tool. Please refer to prior study case 2017-ASO-799-NRA for comments and determination letter. Note this NRA (2021-ASO-6544) is the NRA linked with the new temp locID 9625 which will be used to coordinate with NFDC for a permanent locID.\r\n\r\nLAP ASN # 2021-ESA-188-LAP (Prior Study Case 2017-ASO-799) Construct/Establish Med-Trans Base Heliport in Panama City FL. The proposed helipad will be constructed at ground level (TLOF: 50ft x 50ft FATO: 77ft x 77ft). No IFR procedures are anticipated.
NRAARCH-DeterminedASN 2017-ASO-799-NRA2017-03-15
Form 7480 · 0 ft AGL — Construct/Establish Med-Trans Base Heliport in Panama City FL. The proposed helipad will be constructed at ground level (TLOF: 50ft x 50ft FATO: 77ft x 77ft). No IFR procedures are anticipated.
NRAARCH-DeterminedASN 2010-ASO-1170-NRA2011-01-03
Heliport · 0 ft AGL — This case is for the established of a new private use heliport in Panama City FL. See attached documents for more information.
Blueprint
The record vs. what we measured
73/100
DATA INTEGRITY
eVTOL footprint
The 50 ft pad is 50 ft short of the 100 ft an eVTOL FATO requires (measured).
SIGNALFEDERAL RECORDMEASURED
Surface elevation25 ftnot cross-checked
Structurenot on recordGround-level
Pad dimensions50 ft side (filed)50 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
✓Federal record
→
✓Cross-checkedUSGS · Overture · dimensions
→
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.