AirIndex Research · FAA LID 6FL1

MAYO CLINIC

JACKSONVILLE, FL. Operational · Private use.

OperationalPrivate usePrivate

Watch this facility

Get an email when the record for Mayo Clinic changes: its FAA registration, pad data, nearby FAA airspace determinations, or AirIndex findings. A weekly digest arrives only when something changed.

Already a reader? Sign in to watch it
Loading satellite view…

Data integrity

73/100
CorroboratedData Integrity Index
Independent inspection
Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 15 ft MSL · USGS ground 13 ft · Δ 2 ft
Structure cross-check (Overture / OSM)
Ground-level — no building footprint at the coordinate
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)

Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →

eVTOL readiness

INFEASIBLE WITHOUT REMEDIATIONConversion feasibility · four readings, one line each
Obstruction screen
Severe
High obstacle within 0.5 nm conflicts with the expanded footprint and the 8:1 approach surface.
Geometry
Requires 60 feet of expansion
Recorded pad side 40 ft against a 100 ft eVTOL FATO.
Structural FATO
Unverified
The full 100 × 100 ft FATO must be load-bearing. The FAA does not record structural capacity, so no record can confirm it.
Overall
Infeasible without remediation
A high obstacle conflicts with the expanded footprint. Remediation or a different site.
100 ft · eVTOL FATO40 ft
The recorded pad is 60 ft short of the 100 ft footprint an eVTOL would need — shown to scale.
recorded pad eVTOL FATO
Recorded pad (limiting side)
40 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.

Measured against FAA pad geometry and federal FATO sizing (EB-105). The obstruction screen is the only reading the engine verdict rests on; geometry and structural capacity are stated separately and never folded into it. A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.

FAA compliance

Q1 · FAA registrationPASS
Active FAA NASR 5010 record.
Q2 · Airspace determinationON_FILE
OE3A archive: ASN 2022-ASO-8041-NRA determined 2023-01-03
Q3 · State enforcementSTRONG
State has adopted FAA AC as enforceable.
Q4 · NFPA 418ADOPTED
Jurisdiction has adopted NFPA 418 in fire/building code.

FAA facility data

FAA LID
6FL1
AIX ID
aix:hp:N7PA8XGG
Lat / Lng
30.26501, -81.44265
Elevation
15 ft MSL
Pad dimensions
40 × 40 ft
Surface type
CONC
Activation date
2009/03
Last owner update
2020/05/01

FAA OEAAA airspace determinations3

Airspace clearance
On file as archived / procedural records — no standing clearance to track.
Filing activity
Most recent determination 2022-10-06
  • NRAARCH-DeterminedASN 2022-ASO-8041-NRA
    2023-01-03
    Form 7480 · 0 ft AGL — LAP ASN # 2022-ESA-188-LAP; Proposed temporary relocation of the existing helipad at Mayo Clinic (6FL1) in Jacksonville FL. The helipad is being relocated due to the construction of a 5-story addition in the vicinity of the existing helipad. No IFR Procedures are anticipated for the ground-level temporary helipad.
  • NRAARCH-DeterminedASN 2012-ASO-772-NRA
    2012-06-27
    Heliport · 0 ft AGL — Temporary relocation of existing Mayo Clinic Hospital helipad in Jacksonville FL. Helipad currently located at LAT 30d15'53.9\ LONG 81d26'27.1\ to be relocated to LAT 30d15'54.02\ LONG 81d26'33.45\ Construction of relocated helipad will be from 06/01/12 to 07/01/12. Use of temporarily relocated helipad will be between 07/01/12 and 12/30/13.
  • NRAARCH-DeterminedASN 2007-ASO-736-NRA
    2008-01-22
    Heliport · 0 ft AGL — New Heliport Construction\r\n\r\nSee attached 7480-1 for Heliport Information. \r\n\r\nHard copies will be sent by mail.
Blueprint
The record vs. what we measured
73/100
DATA INTEGRITY
eVTOL footprint
FATO 100 ft reqHTLOF 40 ft

The 40 ft pad is 60 ft short of the 100 ft an eVTOL FATO requires (measured).

SIGNALFEDERAL RECORDMEASURED
Surface elevation15 ftnot cross-checked
Structurenot on recordGround-level
Pad dimensions40 ft side (filed)40 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
Federal record
Cross-checkedUSGS · Overture · dimensions
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.
Request Ground Truth verification

Full risk assessment

This page is the public data-integrity record. The full RiskIndex assessment — Q1–Q5 compliance, dimensional / FATO analysis, an underwriting-grade risk score, peer benchmark, and a sealed Site Intelligence Report — is available on request.

Request the full assessment

Building autonomous systems? See the machine-verified feed

Provenance FAA NASR 5010 · pad dims APT cycle 2026/03/19 · USGS 3DEP terrain · Overture structure · eVTOL screen conversion-feasibility-1.1 · AIX-ID aix:hp:N7PA8XGG · Methodology →
Cite this facility

MAYO CLINIC, JACKSONVILLE, FL (FAA 6FL1). AirIndex facility record aix:hp:N7PA8XGG. Verifiable at https://www.airindex.io/verify/aix:hp:N7PA8XGG.

Verify this record →

AIX-IDs are free to cite and reference; the registry is the source of record. The verify link resolves this record against the audit chain.

← All markets