Get an email when the record for Baptist Hospital changes: its FAA registration, pad data, nearby FAA airspace determinations, or AirIndex findings. A weekly digest arrives only when something changed.
Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 9 ft MSL · USGS ground 7 ft · Δ 2 ft
Structure cross-check (Overture / OSM)
Ground-level — no building footprint at the coordinate
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)
Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →
eVTOL readiness
INFEASIBLE WITHOUT REMEDIATIONConversion feasibility · four readings, one line each
Obstruction screen
Severe
High obstacle within 0.5 nm conflicts with the expanded footprint and the 8:1 approach surface.
Geometry
Requires 25 feet of expansion
Recorded pad side 75 ft against a 100 ft eVTOL FATO.
Structural FATO
Unverified
The full 100 × 100 ft FATO must be load-bearing. The FAA does not record structural capacity, so no record can confirm it.
Overall
Infeasible without remediation
A high obstacle conflicts with the expanded footprint. Remediation or a different site.
The recorded pad is 25 ft short of the 100 ft footprint an eVTOL would need — shown to scale.
recorded pad eVTOL FATO
Recorded pad (limiting side)
75 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.
Measured against FAA pad geometry and federal FATO sizing (EB-105). The obstruction screen is the only reading the engine verdict rests on; geometry and structural capacity are stated separately and never folded into it. A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.
3 structures determined near the pad · tallest 275 ft AGL
Active construction (crane / in-progress) filed recently — obstruction environment is changing.
Filing activity
Most recent determination 2026-08-04 · 3 in the last 24 months
NRAARCH-Work In ProgressASN 2003-ASO-416-NRA
Other · 0 ft AGL — PRIVATE-USE/PRIVATE-OWN HOSPITAL HELIPORT - MOVING CURRENT PAD 100 YDS SE OF CURRENT SITE. 3 PRIVATE USE LANDING FACILITIES WITHIN 5 NM: 2FAO FL76 FL94. HARD COPY TO MIA-FSDO
CRANE$TOWER · 169 ft AGL — Baptist Hospital KCG and NTWR
NRAARCH-DeterminedASN 2019-ASO-5783-NRA2020-04-06
Form 7480 · 80 ft AGL — LAP ASN # 2019-ESA-66-LAP; Proposed new rooftop helipad (H2) at Baptist Hospital (9FA8) Miami FL. The 65' x 65' helipad will be constructed 91ft AGL. No IFR procedures anticipated.
NRAARCH-DeterminedASN 2013-ASO-227-NRA2013-05-10
Heliport · 0 ft AGL — RELOCATION and TRAFFIC PATTERN CHANGE to existing Baptist Hospital helipad (9FA8) in Miami FL. Relocate from 25d 40' 01.37\ / 80d 19' 59.19\ to 25d 41' 09.87\ / 80d 20' 18.52\. Traffic pattern change from NE approach/departure to NW approach/departure.
Blueprint
The record vs. what we measured
57/100
DATA INTEGRITY
eVTOL footprint
The 75 ft pad is 25 ft short of the 100 ft an eVTOL FATO requires (measured).
SIGNALFEDERAL RECORDMEASURED
Surface elevation9 ftnot cross-checked
Structurenot on recordGround-level
Pad dimensions75 ft side (filed)75 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
✓Federal record
→
✓Cross-checkedUSGS · Overture · dimensions
→
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.