Owner self-reported — never independently field-inspected
Location confidence
No coordinate anomaly detected
Terrain cross-check (USGS 3DEP)
FAA 560.6 ft MSL · USGS ground 552 ft · Δ 9 ft
Structure cross-check (Overture / OSM)
Ground-level — no building footprint at the coordinate
Cross-source consensus
Corroborated — terrain and structure agree (2/2 sources)
Cross-checked against independent public data — USGS 3DEP terrain, Overture/OSM building footprints, the federal hospital registry, and measured dimensions. The State of the U.S. Heliport Record →
This pad already covers the eVTOL landing footprint as it stands.
recorded pad eVTOL FATO
Recorded pad (limiting side)
100 ft
eVTOL FATO required
100 ft
FAA EB-105 vertiport pattern — 2× a ~50 ft eVTOL controlling dimension, plus a 125 ft safety-area side.
Load-bearing FATO
100 × 100 ft must be structural
No heliport precedent — typically the binding gate for rooftop and hospital pads.
Obstruction clearance
Clear — no obstructions within 0.5 nm on the FAA obstacle file
Measured against FAA pad geometry and federal FATO sizing (EB-105). A dimensional pre-screen — site-level validation required, and independent of the underwriting risk score.
IBC references NFPA 418 for rooftop facilities. Standalone fire code reference not confirmed.
FAA facility data
FAA LID
TS23
AIX ID
aix:hp:68VWVEMW
Lat / Lng
30.33774, -97.90594
Elevation
560.6 ft MSL
Pad dimensions
100 × 100 ft
Surface type
CONC
Activation date
2002/02
Last owner update
2000/11/01
FAA OEAAA airspace determinations1
Airspace clearance
On file as archived / procedural records — no standing clearance to track.
Filing activity
Most recent determination 2000-03-16
NRAARCH-DeterminedASN 2000-ASW-5525-NRA2000-05-03
Other · 0 ft AGL — ESTABLISH PRIVATE HELIPORT
Blueprint
The record vs. what we measured
73/100
DATA INTEGRITY
eVTOL footprint
Footprint assessment available.
SIGNALFEDERAL RECORDMEASURED
Surface elevation560.6 ftnot cross-checked
Structurenot on recordGround-level
Pad dimensions100 ft side (filed)100 ft side · measured
Coordinate integrityas filedterrain cross-checked
Independent inspectionowner self-reportednone on record
✓Federal record
→
✓Cross-checkedUSGS · Overture · dimensions
→
3Physically verifiedGround Truth capture
Obstructions, exact FATO geometry, surface condition, and downwash exposure require a physical Ground Truth capture — not shown above as measured. A field verification completes the record and writes the measured truth to this facility’s authority.